Sheet Busbar Insulation
video
Sheet Busbar Insulation

Sheet Busbar Insulation

Sheet busbar insulation is a high performance product specially designed to provide insulation, sealing and protection for busbars. It is made of special heat-shrinkable material and can be tightly shrink-wrapped on the busbar surface after heating, effectively improving the safety, reliability and service life of the busbar. It is widely used in power systems, electrical equipment and other fields.

  • Fast Delievery
  • Quality Assurance
  • 24/7 Customer Service
Product Introduction
Product Profile

 

Sheet busbar insulation is a heat shrinkable tube specially designed to provide insulation, protection and identification functions for busbar systems. It is made of high quality polymer material and processed with a special process. It can be tightly shrink wrapped on the surface of the busbar when heated, providing all round protection for the busbar.

 

Busbar Insulation Sheet

 

 

Product Features

 

Product Features

 

High insulation resistance

The heat shrinkable tube busbar has extremely high insulation resistance. For example, the insulation resistance can reach more than 10¹⁴Ω·cm at normal temperature, which effectively prevents current leakage and ensures the safe operation of the busbar in high voltage environments.

Excellent dielectric strength

The dielectric strength reaches 20kV/mm, which can withstand high electric field intensity without breakdown, providing a reliable insulation barrier for the busbar.

Heat Shrink BusBar
Heat Shrink Tube Polyolefin Busbar

Good fit

After heating, it can fit perfectly with the busbar surface without bubbles or gaps, effectively preventing dust, moisture, corrosive gases, etc. from intruding into the busbar and protecting the busbar from external environmental factors.

Mechanically reliable

The tensile strength is between 10 - 15MPa, which can withstand the external force stretching that may be encountered during installation and use, ensuring that it will not be damaged under normal operation.

quality and service
​ Quality control system
We follow a strict quality management system and conduct strict quality control in every step from raw material procurement, production and processing to product testing. Advanced production equipment and process technology are used to ensure product consistency and stability.
Customized services
If customers have special size, shape, performance requirements or surface treatment requirements, we can customize production according to customer requirements to ensure that customers' individual needs are met.
After-sales service
We have a professional technical support team that can provide customers with a full range of technical support services. Whether it is product selection, installation and commissioning, or troubleshooting, our technical staff can respond to customers' needs in a timely manner and provide effective solutions.
product specifications

 

Dimensions A variety of inner diameter specifications are available, from 5mm - 100mm, to accommodate busbars of different sizes. The wall thickness is between 0.5mm - 3mm, and different wall thicknesses can meet different insulation and mechanical strength requirements.
Color Selection A variety of standard colors are provided, such as red, yellow, blue, green, black, etc., allowing users to choose according to phase sequence or other marking requirements. Colors can also be customized according to customers' special requirements.

 

Busbar Sleeves Insulation

 

 

 

Installation guide

 

Preparation Make sure the busbar surface is clean, dry, and free of oil, dust, oxides and other impurities. Select the heat shrinkable tube busbar of appropriate specifications according to the size of the busbar. The inner diameter of the heat shrinkable tube busbar should be slightly larger than the outer diameter of the busbar.
Heat Shrinkage Use a heat gun, oven, or other suitable heating device to heat the heat shrink tubing busbar. When heating, start from one end and move the heating equipment slowly and evenly to gradually shrink the heat shrink tube busbar. The heating temperature should be controlled between 120℃ - 150℃ to avoid local overheating.
Check And Adjust After the heating shrinkage is completed, check whether the heat shrinkable tube busbar completely fits the surface of the busbar. If there are bubbles or unfitted parts, additional heating can be applied to make adjustments.

 

 

 

 

MsTina Xiamen Apollo

 

 

 

 

 

 

Regularly check the appearance of the heat shrink tube busbar to see if there is any damage, aging, discoloration, etc. If problems are found, they should be replaced in time. When maintaining, inspecting or operating the busbar, avoid scratching the heat shrink tube busbar with sharp objects to avoid affecting its insulation and protective performance.

Hot Tags: sheet busbar insulation, China, manufacturers, suppliers, factory, Copper Cap And Fuse Terminal Contact, Fuse Copper Cap, Fuse Link Contact For Communications, Fuse Cap, Fuse Copper T2Y2 Holders, Fuse Contact And End Caps Components

You Might Also Like

(0/10)

clearall